KINGTEC S393 / S393E Transport Refrigeration Units


KINGTEC S533

Kingtec S393 / S533 series units are designed for frozen and fresh applications on the 15~31m3 mini refrigeration trucks.The road compressor is powered by the vehicle engine. While the unit with a second compressor it is powered by an electric motor. The stand-by unit is installed on the skirt of the truck.

KINGTEC S533
EVK400 evaporator

REFRIGERATION CAPACITY

30°C(86°F) ambient temperature
ATP Standard
100°F(38°C) ambient temperature
US-Standard
S393 (R404A) S393 (R404A)
Air return/on the road Watts BTU/hr Air return/on the road Watts BTU/hr
0°C(32°F) 4430 15100 2°C(35°F) 4050 13800
-20°C(-4°F) 2220 7575 -18°C(0°F) 2030 6900
50Hz electrical stand-by operation 60Hz electrical stand-by operation
0°C(32°F) 3420 11670 2°C(35°F) 3550 12100
-20°C(-4°F) 1850 6310 -18°C(0°F) 1900 6480

LAE Control Panel

LAE Control Panel

SYSTEM COMPONENTS

  • Condenser assembly
  • Evaporator assembly
  • Swash plate road compressor (With magnetic clutch)
  • Incab control box and wiring harness
  • Optional heating funtion:(Hot gas heating system or engine water heating
    system)

ROAD COMPRESSOR (ENGINE DRIVEN)

  • Swash plate road compressor
  • Displacement: 162cc
  • Max recommended speed: 3000rpm
  • Includes oil return separator

AIRFLOW VOLUME

EVK400 Evaporator 1650m3/h (970cu ft/min)

REFRIGERENT (CHLORINE ZERO)

  • S393 (R404a): HFC R404A 2.3kg

ELECTRICAL SPECIFICATION

  • DC voltage options: DC12V or DC24V
  • Total current consumption on the road (Road compressor)
DC12V DC24V
S393 48.4A 25.5A
  • Total stand-by current consumption
S393
230V/1Phase/50Hz 13.6a
230V/1Phase/60Hz 13.6a
230V/3Phase/50Hz 13.6a
230V/3Phase/60Hz 13.6a

WEIGHTS (APPROXIMATE)

  • S393 Condenser (with stand-by): 85(125)kg/187(276)Lb
  • EVK300C evaporator: 32kg/71Lb

WARRANTY SUMMARY

Specific terms of the Kingtec express warranty are available on request. Further, Kingtec excludes liability in contract and tort (including strict liability and negligence) for any special, indirect or consequential damages by reason of the installation or use of any covered product or its mechanical failure.