HYD COMPRESSOR DRIVE OPEN CENTER LOOP SYSTEM 12vdc
P-9976-29, Compressor Model Type-2 QP-31-R134a, Maximum 3000 Rpm Rotation Clockwise Only
Input Hydraulic Power Requirement 27 – 30 HP or 20 – 22kw
Hydraulic Drive motor rates at 63.5 Nm (47 Ft/lbs) torque @ 26 gpm (100 L/Min)
Min 2000 Psi to Max 3400 psi!
Adjust Flow Control on Polar block so we do not Exceed 2700 RPM Compressor Speed!
Refrigeration capacity is at 2700 rpm 47,000 BTU/HR (13.87 KW)
Calculated at Evap Gas Temperature of 36F / 2C & Inlet Evap Air Temp of 76F / 24C